Control Simulator is free while it's in beta. Join the beta
FOR HVAC DESIGN ENGINEERS

Test your control sequences before they reach site.

Draw your system, press play and watch it run. Control Simulator then writes your Functional Description and points list from the same model.

Try it free Watch it run
CS Control Simulator REVIEW COPY Sample office AHU Rev A
Mon 
Supply air Exhaust air Control links
Area 60 – AHU-01 Level 1 Office °C Outdoor · mean 27 °C TIME SCHEDULE 60-TS-01 State Today 07:00–18:00 60-AHU-01 OA MA HTG CLG SA 60-ZN-01 Level 1 open office °C set 21–24 °C CO₂ ppm · m³/h · people 60-EF-07 AHU CONTROLLER 60-AHC-01 Mode Setpoints 21 / 24 °C · OA TIT 01 °C PDIT 03 kPa FS 04 TIT 02 TIT 05 °C AIT 06 ppm
Functional description Points list

A live preview of the sample office AHU, made lighter to run on this page. Press any button in the toolbar, or try these:

WHAT THIS ONE SAMPLE MODEL PRODUCED
8
operating modes, each one tested
~3,300
words of Functional Description
24
points in the points list
10
alarms, with priorities and delays
0
documents to keep in sync by hand
HOW IT WORKS

Four steps. One model.

STEP 1

Draw your system

Add AHUs, chillers, pumps, valves and sensors. Set your schedules, setpoints and interlocks.

STEP 2

Press play

Watch a full day run in a few minutes. Trip a fan or set off the fire alarm and see what happens.

STEP 3

Download your documents

Get the Functional Description in Word and the points list in Excel, both from the model you just tested.

STEP 4

Share it with your client

Send one file. Your client opens it in a browser and tests it themselves.

THE PROBLEM

Control logic is usually tested last, on site.

Problems show up late

Most sequences are first tested at commissioning. By then, every fix costs time and money.

Documents don't match

The FD and the points list are separate files, written by hand. Change one, and the other is out of date.

Clients have to imagine it

Reviewers read pages of text and guess how the plant will behave. Questions come up late.

SIMULATION

See every mode switch on and off.

Control Simulator runs your logic through a whole day. You see which mode takes over, when it happens and why.

  • Schedules, pre-cooling and night purge
  • Free cooling and CO₂-based fresh air
  • Duty and standby pumps and chillers
  • Trips, sensor faults, fire mode and alarms
THE 8 MODES IN THE SAMPLE, MOST IMPORTANT FIRST
1Fire modeFire alarm: fan stops, dampers shut
2Frost tripAir off the coil below 4 °C: unit stops
3OccupiedOffice open: keep it between 21 and 24 °C
4Optimum startPre-cool or pre-heat 1 hour before opening
5Night purgeFlush the office with cool night air
6Night setbackOffice below 15 °C: heat it back to 17 °C
7Frost protectionOutside below 3 °C: keep the coil warm
8UnoccupiedNothing else needed: plant off
Functional Description
FD-60-001 · AHU-01 Level 1 Office · Rev A
1 Introduction
2 Normal automatic operation
Modes · Temperature control · CO₂ ventilation · Schedule · Fans · Sensors · Setpoints
3 Failures
Power · Equipment · Sensors
4 Alarms
5 Off-normal functions
6 Abnormal operation
E-stop · Fire alarm · Manual control
7 Operator screens
FUNCTIONAL DESCRIPTION

Your FD, written for you.

Control Simulator writes the FD from your model: equipment, modes, control, interlocks, setpoints, failures and alarms. Change the model, and the FD changes with it.

Download it in Word. Check it and add your project wording before you issue it.

POINTS LIST

Your points list, counted for you.

Every input and output, with its tag, signal type, range, alarm and trend. Plus a summary with 20% spare. Your controls contractor can price from it straight away.

DI
9
DO
2
AI
7
AO
4
22 hardwired · 27 with spare · download in Excel
POINT TAGDESCRIPTIONTYPESIGNALALARM
60-AHU-01-SPDSupply fan speedAO4–20 mA—
60-AHU-01-OADOutside air damperAO0–10 V—
60-PDIT-03-PVFilter pressure dropAI4–20 mAHigh 0.25 (Low)
60-AIT-06-PVOffice CO₂AI4–20 mAHigh 1500 (Warning)
60-FS-04-SAirflow failureDIVolt-freeActive (High)
60-AHC-01-FAFire alarm signalDIVolt-freeFire (Critical)
sample-office-ahu-rev-A.html
Opens in any browser. Nothing to install.
Your client runs it themselves
They can test failures and alarms
They can't change your design
REVIEW COPIES

Let clients try it, not just read it.

Send each revision as one file. Your client opens it, presses play, trips a fan or sets off the fire alarm, and sees what happens. Questions get answered before site.

SYSTEMS

From one AHU to a whole plant room.

Another sample: two 560 kW chillers, six pumps and 30 fan coil units, with a 441-point list. We're starting with HVAC. Water and wastewater already work too.

Air handling units
Chillers and heat pumps
Chilled and heating water pumps
Fan coil units and zones
Supply and exhaust fans
Schedules and weather
WHO IT'S FOR

Mechanical engineers and building services consultants

You write the control philosophy. Control Simulator helps you test it, then hand over an FD and points list that match.

WHAT IT ISN'T

It doesn't replace BMS programming software

Controls contractors keep their own tools. Control Simulator gives them a clearer, tested design to build from.

FREE WHILE IN BETA

Help shape Control Simulator.

We're looking for practising HVAC engineers. Try it on a project, then tell us what works and what's missing.

Join the beta Book a demo